ASK A QUESTION ask a question

AW 634AHC-7034BHC

Especially designed for swimming pools in the Gulf climate, the 34 range is particularly suitable for ducted installation within a plant room, or for outdoor installation. Not to be confused with converted condensing units or modified heat pumps originally for a different purpose. Every aspect of Calorex 34 Heat Cool units are designed to give optimum performance and reliability even in the toughest climates.

AW 7034BC Side
AW 7034BC Back
AW 7034 Control Panel
  • Features

    • Designed for the Gulf climate
    • Reduced energy consumption
    • No additional equipment required
    • Simple installation and long service life
    • Suitable for all year round pool use
    • Minimal maintenance
    • Low operating cost
    • Zero ozone depleting R134a refrigerant - unlike R22 and R407C, R134a will operate reliably throughout every possible Gulf climatic condition
    • Fully automatic operation
    • Water flow switch (only 3034 & 7034 models)
    • Weather and corrosion resistant construction including plastisol coated galvanised steel cabinet and epoxy coated coils
    • 90/10 marine grade heat exchangers

    Options

    • Chiller or heater only
    • Rear or top outlet on 3034 or 7034
    • Soft start
    • High pressure fan
    • 3ph, 60Hz versions​

    Applications

    • Outdoor and indoor pools (Gulf and SE Asia)
    • Health clubs and wellness centres
    • Hotels and spa pools
  • Middle East

    Heat cool units designed for the Gulf climate...read more

  • Pool Catalogue

    Dantherm Group

    Pool Catalogue

    Product Catalogue

    Calorex

    Product Catalogue

  • Specifications Units AW 634AHC AW 1234BHC AW 3034BHC AW 7034BHC
    Air temperature range °C 10-55 10-55 10-55 10-55
    Water temperature range °C 10-40 10-40 10-40 10-40
    Heating output @+20°C/85% RH ambient kW 7.4 11.8 35.4 60.0
    Heating input @+20°C/85% RH ambient kW 1.3 2.1 6.6 10.8
    Cooling output @+45°C/50% RH ambient kW 5.5 9.8 29.2 49.5
    Heating input @+20°C/85% RH ambient kW 1.9 3.2 9.9 16.3
    Power supply V/Hz 240/1ph/50 400/3ph/50 400/3ph/50 400/3ph/50
    Recommended maximum supply & fuse capacity A 20 16 35 60
    Maximum starting current standard (LRA) A 32 48 126 126
    Nominal air flow m3/h 1500 3000 10000 11700
    Fan external resistance (standard) Pa 50 0 0 0
    High pressure fan Pa Variable to meet customer requirements
    Water flow ±10% l/min 33 33 66 130
    Pressure drop (water) m hd 2.1 2.2 2.5 5.3
    Water connections inch ¾ ¾
    Condensate water connections inch ¾ BSPM ¾ BSPM 1½ BSPM 1½ BSPM
    Compressor Type 1 x Recip 1 x Scroll 1 x Scroll 1 x Scroll
    Fan Type ‹ 1 x Centrifrugal ›
    Sound level @ 3m dB(A) 63 65 72 68
    Width mm 820 1060 1700 1950
    Depth mm 702 705 1090 1340
    Height mm 762 807 1212 1212
    Weight kg 111 157 411 690
    Output and input calculated at water temperature 26°C for heating, and 32° for cooling
Pool
  • linkedin
  • youtube

Contact (International)

+44 (0)1621 856 611

International Enquiries


Contact (UK)

Certikin International Ltd (H&V Department) 01993 778855

Contact Certikin