Pro-Pac heat cool
Pro-Pac heat cool

ASK A QUESTION ask a question

Pro-Pac 16BHC-140BHC

​​Heat Cool units are designed for non-ducted plant rooms or outdoor installation and offer an economic solution to swimming pool heating and cooling, with the same reliability and efficiency as 34 range units.

Pro-Pac 90
Pro-Pac control panel
  • Features

    • Capacities from 13kW to 140kW
    • Zero ozone depleting R134a refrigerant – ensures reliable, efficient operation regardless of air temperature
    • Titanium or CuNi heat exchanger
    • Designed and manufactured in the UK
    • Fully automatic operation
    • Scroll compressors
    • Water flow switch on all models
    • Comprehensive circuit protection
    • Quiet, efficient owlet axial fans
    • Weather-proof construction
    • Digital thermostat

    Options

    • Chiller only
    • Heater only
    • 3ph, 60Hz versions
    • Soft start
    • High pressure fan
    • Condensate insulation kit for plant room installations

    Applications

    • Outdoor and indoor pools (Gulf and SE Asia)
    • Health clubs and wellness centres
    • Hotels and spa pools
  • Middle East

    Heat cool units designed for the Gulf climate...read more

  • Pool Catalogue

    Dantherm Group

    Pool Catalogue

    Product Catalogue

    Calorex

    Product Catalogue

  • Specifications Units PRO-PAC 16BHC PRO-PAC 22BHC PRO-PAC 30BHC PRO-PAC 45BHC PRO-PAC 70BHC PRO-PAC 90BHC PRO-PAC 140BHC
    Air temperature range °C 10-55 10-55 10-55 10-55 10-55 10-55 10-55
    Water temperature range °C 10-38 10-38 10-40 10-40 10-40 10-40 10-40
    Heating output @+20°C/85% RH ambient kW 11.8 15.0 31.0 36.4 61.9 72.7 123.8
    Heating input @+20°C/85% RH ambient kW 2.1 2.7 5.5 6.7 10.5 13.3 21.0
    Cooling output @+45°C/50% RH ambient kW 9.8 12.4 25.5 30.0 51.0 59.9 102.1
    Cooling input @+45°C/50% RH ambient kW 3.2 4.1 8.3 10.0 16.2 20.0 32.4
    Power supply V/Hz 400/3ph/50 400/3ph/50 400/3ph/50 400/3ph/50 400/3ph/50 400/3ph/50 400/3ph/50
    Minimum supply capacity A 10 13 21 25 42 50 84
    Recommended supply fuse A 16 20 30 40 60 70 125
    Max. starting current standard (LRA) A 48 48 96 102 96 102 96
    Max. starting current soft start (LRA) A 25 25 33 34 33 34 33
    Nominal air flow m3/h 4000 5000 5500 11000 14000 22000 28000
    Fan external resistance (standard) Pa 0 0 0 0 0 0 0
    Water flow ± 10% (CuNi/Titanium heat exchanger) l/min n/a/123 n/a/123 n/a/250 66/300 133/500 166/600 266/1000
    Pressure drop (water) m hd inch n/a/0.2 n/a/0.2 n/a/0.7 4.5/0.4 3.4/1.5 4.5/1.7 5.3/2.1
    Water connections inch 1½ F/PVC 1½ F/PVC n/a/2 union 1½ BSPM/2 union 1½/3 BSPM 1½/3 BSPM 2/4 BSPM
    Condensate water connections " BSPM ½ ABS ½ ABS
    Compressor Type 1 x Scroll 1 x Scroll 1 x Scroll 1 x Scroll 2 x Scroll 2 x Scroll 4 x Scroll
    Fan Type 1 x Axial 1 x Axial 1 x Axial 1 x Axial 1 x Axial 2 x Axial 2 x Axial
    Sound level @ 3m dB(A) 48 52 64 65 70 65 70
    Width mm 1264 1264 1525 1665 1810 2065 2210
    Depth mm 600 600 790 1060 1190 1190 1650
    Height mm 725 725 1080 1310 1310 1330 1340
    Weight kg 131 145 219 329 549 599 1065
    Output and input calculated at water temperature 26°C for heating, and 32° for cooling