Dantherm

Contact us  ask a question

HCV 300 - 700

A good indoor climate determines the health and well-being of the entire family and protects buildings and interior from moisture damage.

The HCV range of residential ventilation units has built-in RH sensors automatically adjusting air volumes in relation to the relative humidity in the home. This means that there is no need to wire the unit up to external sensors.The HCV units are constructed with a new, light-weight aluminium counter flow heat exchanger developed and manufactured by Dantherm, which has an efficiency level of up to 95%.

  • Features

    • Demand-controlled ventilation with integrated humidity sensor
    • This reduces power consumption at times with low ventilation demands
    • Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature
    • Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality
    • High efficiency heat recovery
    • EC fan motors with extremely low energy consumption (low SPI)
    • Easy-to-install and commission solution with built -in air pressure spigots for easy calibration
    • Highly customizable units, by adding a high variety of internal as well as external accessories
    • HCV models takes up only as little space as a 60x60cm cupboard

    Applications​

    • Private houses
    • Villas
    • Apartments
  • Residential Catalogue

    Dantherm Group

    Residential Catalogue

  • Specifications Units HCV 300 HCV 500 HCV 700
    Max. air flow (max. @ 100 Pa) m³/h 275 375 550
    Bypass Yes, automatic Yes, automatic Yes, automatic
    Performance
    Energy consumption class (SEC-class), average climate A A A
    Energy consumption class (SEC-class), average climate A+1 A+1 A+1
    Efficiency EN13141-7 dry (ηSUP) % 86 86 85
    Installation surrounding temperature °C 12 - 50 12 - 50 12 - 50
    Outdoor temperature without preheater installed (tODA) °C -12 - +50 -12 - +50 -12 - +50
    Outdoor temperature with preheater installed °C -25 - +50 -25 - +50 -25 - +50
    Cabinet
    Product size (w x h x d without bracket) mm 600 x 1000 x 430 700 x 1050 x 603 700 x 1050 x 750
    Ducts Ø mm 125 - female 160 - female 200 - female
    Weight kg 36.5 49.5 70
    Fire classification of the unit EN 13501 class E EN 13501 class E EN 13501 class E
    Drainage hose included (Ø/length) "/m ¾" - 1m ¾" - 1m ¾" - 1m
    Electrical
    Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50
    Max. power consumption (without heater options fitted) W 170 170 234